Exterior walls parallel to a braced wall line shall be offset not more than 4 feet 1219 mm from the designated braced wall line location as shown in figure r602 10 1 1 interior walls used as bracing shall be offset not more than 4 feet 1219 mm from a braced wall line through the interior of the building as shown in figure r602 10 1 1.
Nc braced wall panels shall begin no more than.
Braced wall panels shall be full height wall sections sheathed with the materials listed in section r602 12 1 and complying with the following.
20 feet r602 10 2 2 where located in seismic design category d a brace wall line of 18 feet shall have no less than braced wall panels.
Located every 25 feet on center.
Exterior braced wall panels shall have a minimum length based on the height of the adjacent opening as specified in table r602 12 2 panels with openings on both sides of differing heights shall be governed by the taller opening when determining panel.
Than 12 5 feet from each end of a braced wall line per figures 21 25 a and 21 25 b and shall be.
See attachment in link the design of the lower level braced wall compose of three 20 cs pf panels.
Either 1 a minimum 24 wide panel is applied to each side of the building corner and the two 24 panels at the corner are attached to framing in accordance with.
Alternate braced wall lines constructed in accordance with one of the following provisions shall be permitted to replace each 4 feet 1219 mm of bracedwall panel as required by section r602 10 4.
R602 10 6 1 alternate braced wall panels.
The distance between adjacent edges of braced wall panels along a braced wall line shall be no greater than 20 feet 6096 mm as shown in figure r602 10 2 2.
The braced wall panel shall be permitted to begin no more than 8 ft from each end of the braced wall line provided the following occurs.
These panels shall begin no more than 10 feet from each end of a braced wall line and the distance between adjacent edges of braced wall panels shall be no greater than 20 feet figure r602 10 2 2.
A minimum 2 foot long 610 mm full height wood structural panel is.
For the intermittent braced wall method wsp.
The distance between adjacent edges of braced wall panels along a braced wall line must be a maximum of feet.
I read ibc 2012 2308 12 6 irregular structures 3.
The first braced wall panel shall be permitted to begin 12 feet 6 inches 3810 mm from each end of the braced wall line in seismic design categories a b and c and 8 feet in seismic design categories d 0 d 1 and d 2 provided one of the following is satisfied.
Braced wall lines are basic elements in conventional light frame construction and shall consist of braced wall panels.
R602 10 2 2 locations of braced wall panels.
A braced wall panel shall begin within 10 feet 3810 mm from each end of a braced wall line as determined in section r602 10 1 1.
Bracing amounts shall comply with table 21 25 h for the.
Bracing materials and methods specified under par.